JKLD50kW-102kWh-A

Category: All-in-one

High reliability, supporting constant 110% overload and 120% overload for 60 seconds.

More than 6000 charging cycles.

Multiple protection mechanisms to ensure safe operations.

5 working modes for various application scenarios.

Supporting diesel generators for diverse   energy sources.

Supporting parallel connections for higher adaptability.


Get A Quote

JKLD50kW-102kWh-A

High Reliability:110% continuous overload, 120% overload for 60s

Long Cycle Life:>6000 cycles at 80% DoD

Intelligent Protection:Multi-layer safety mechanisms

Flexible Operation:5 working modes for diverse scenarios

Multi-Source Integration:Compatible with diesel generators and PV input

Parallel Operation:High adaptability in different scenarios 

Microgrid-friendly:Supporting microgrid systems, peak-shaving and valley-filling,dynamic capacity expansion, and seamless off-grid and on-grid switching.

System Diagram

11.jpg

Specifications

ModelJKLD50kW-102kWh-A
Battery
Rated Voltage(kWh)102
Range Voltage(VDC)512
Voltage Range(VDC)400~584
Standard Charge/Discharge Rate(C)0.5
Maximum Charge/Discharge Rate(C)1
Inverter
On-grid/Off-grid Rated Power(W)50000
Maximum On-grid Output Apparent Power(W)55000
Rated Output Voltage(V)3L/N/PE; 220/380;230/400;240/415
Rated Output Frequency(Hz)50/60
Maximum On-grid Output Current(A)83
Maximum Off-grid Output Power(VA)55000
Maximum Off-grid Output Current(A)83
Off-grid Rated Output Voltage Frequency(V)3L/N/PE; 220/380;230/400;240/415
Off-grid Rated Output Frequency(HZ)50/60
Maximum PV Input Power(W)75000
Maximum PV Input Voltage(V)1000
MPPT Voltage Range(V)200~850
Start-up Voltage(V)135
MPPT Maximum Input Current per String(A)30/30
MPPT Maximum Short-circuit Current per String(A)40/40
Number of MPPTs4
Number of Input Strings per MPPT2/2/2/2
Maximum Efficiency98.8%
Total Harmonic Distortion of Output Voltage (Linear Load)<3%
Cabinet
Weight(Kg)1200
Dimensions (mm)(W×H×D)1050*1340*2200
IP RatingIP54
Cooling MethodAir conditiooner
Operating Temperature Range(℃)Charge:0~55/Discharge:-20~60/Storage:-10~45
Relative Humidity5~95%,non-condensing
Communication MethodCAN, RS485,RS232
Protection & AlarmsAvailable
LED IndicatorsAlarm / Running / SOC
InstallationDecentralized on-site deployment


Related Products

JKLD-51.2V200AH

JKLD-51.2V200AH

JKLD11000-48P

JKLD11000-48P

JKLD-25.6V100AH

JKLD-25.6V100AH

Intelligent Micro-grid System

Intelligent Micro-grid System

Get A Quote

If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!